Location connection head according to din 43 729 form b environmental ambient40 to 185f 40 to 85c storage40 to 212f 40 to 100c climate class as per iec 60 6541, class c ingress protection ip00 ip66 installed in appropriate housing shock and vibration 4g 2 to 150 hz as per iec 60 06826 emc immunity see table 2. Pt100 iec 751 resolution datasheet, cross reference, circuit and application notes in pdf format. Due to the interchangeability tolerance of the rtds, the jms type e matches both din 43760 iec 751, and. Terminal block ceramic spring loaded 41mm od, 33 pcd. Due to the interchangeability tolerance of the rtds, the jms type e matches both din 43760 iec 751, and british standard bs 1904 curves. Din 43760 iec 751, and british standard bs 1904 curves. The next version of the specification, din 43760 sept 87, applied only to nickel elements, and no longer applied to platinum elements. Other standards such as din 43760, bs1904, bs en60751 1996, and jis c1604 generally match the iec 751. Rtd standards sama, gost, oiml, jemima, bs, jis, din, astm, iec most of these specs have identical class names, but not always identical tolerance values. Din 43760 iec 751 m, a 8 din panel mount universal temperature process indicators 1 omega sm care, pt%rhpt pt10%rhpt pt30% rh pt6% rh rtd maximum range 100 to 900ac 140 to 1650af 100 to 0ac.
Din en 60751 is the applicable din specification for platinum rtd elements. Ppg series thin film platinum rtds mouser electronics. Din iec 751 temperatureresistance table for platinum. In accordance with iec751 din 43760 class b or a conductor. Keep up to date with new publication releases and announcements with our free iec just published email newsletter. Sama standard rc2141966, has a temperature coefficient of. Temperatureresistance table nominal resistance for pt iooq. Prosense din rail mounted temperature transmitters part no. Span pcs pkg wtlb price xtd0unv pt100 rtd pt500 rtd pt rtd to iec.
A tdi quality assurance manual is available to any prospective customer upon. The sama 100 ohm nominal element only has a resistance of 98. Input type programmable measuring range limits min. The first thing is to understand the meaning of the percentage values often used to differentiate tolerance classes. Iec 751, the most commonly used standard for platinum rtds defines two performance classes for 100v, 0.
Standards defining temperature sensors burns engineering. The rtd temperature sensor allows ease of field wiring with conventional heat tracing connection kits. Temperature specialists is a custom manufacturer of quality rtd elements. These standards specify rtd parameters, which include. These performance classes also known as din a and din b due to din 43760 define tolerances on ice point and temperature accuracy. Hand made platinum resistance temperature detectors. Din 43760 sept 68 applied to both 100 ohm nickel and platinum rtd elements. Operating type resistance coefficient range ba1k375 1 k. B type measurement accuracy 1 1 % is related to the adjusted measurement range the value to be applied is the greater. We manufacture custom rtds and standard sensors with a variety of diameters and lengths that meet industrial standards such as iec 751, din 43760, and jisc160481. T0hc standards din 4371 iec 584 retd maximum rang cemaximum rang faccuracy % of reading p0t100 0200 to 60 r325 to 110 0. The din specification is basically the iec spec with a cover page added. Temperatureresistance table nominal resistance for pt.
Pt 100 iec 751 datasheet, cross reference, circuit and application notes in pdf format. According to din 43760, there are 2 classes of rtds while astm e 17 recognizes 2 grades. Model ts1023 does not meet these specifications with a t. Rtd tolerances accuracy or more properly, tolerance, for rtds is stated at one point only, usually 0 deg. The rtd5003 is designed for use as control input for freeze protection and temperature maintenance applications requiring pipewall or tankwall temperature sensing. Span pcs pkg wtlb price xtd0unv pt100 rtd pt500 rtd pt rtd to iec 751 a0. The lements listed below meet the din 43760 and iec 751 specifications, with the temperature coefficient of resistance t. Temperature resistance characteristics conform to din 43760 iec 751 bss 1904 jis c1604 standards. Thin film elements conform to the european curve din 43760 standards and the 0. Frequently asked questions about platinum rtd elements. The iec 60751 and din en 60751 specifications are identical. Thin film elements conform to the european curvedin 43760 standards and the 0.
Iec 751, the most commonly used standard for platinum rtds defines two. Din 437601980, iec pub 7511983, jis c16041989 sensor reference temp. Rtd questions and answers resistance thermometer questions. R0, alpha, tolerance classifications, and coefficients in the. Per astm e17, din standard 43760bs1904iec 751 temperature coefficient. Class a rtd p100 highest rtd p100 element tolerance and accuracy, class a iec 751, alpha 0. Minco components what is class a and class b tolerance. Another standard, astm e17, uses the same nominal characteristic curve, but defines tolerances differently, and designates them as grade b and grade a.
The elements listed below meet the din 43760 and iec 751 specifications, with the temperature coefficient of resistance t. Form number f0380000 revision 0 2000 lake shore cryotronics, inc. Among them are iec 751, din 43760, en 60751, and bs en 60751. We manufacture custom rtds and standard sensors with a variety of diameters and lengths that meet industrial standards. Resistance temperature detectors rtds thermo sensors. Higher temperature ratings are available by special order high accuracy. This element is in common use and should not be confused with the more. Temperatureresistance table nominal resistance for pt iooq element rol. Due to the interchangeability tolerance of the rtds, the jms type e matches both. The rtd100 is designed for use as control input for freeze protection and temperature maintenance applications. Las termorresistencias y su representacion segun las normas.
Din iec 751 temperatureresistance table for platinum sensors. Rtd, 3wire platinum, 100 per din 43760 standard iec751, with range of 0 to 400. Adaptable for use with a variety of enclosure and mounting methods. Tolerances for platinum resistance detectors to bs en 60751. Due to the interchangeability tolerance of the rtds, the jms type e matches. Iec iec 751 din din 43760 insertion length of il mm element 1 pt. Class a rtd p100 highest rtd p100 element tolerance and accuracy, class. Pt500 iec 751 resistance characteristic ni resistance characteristic pt w5rew26re ni din 43760 pt100 iec 751 accuracy ni100 sensor pt100 420 ma rtd pt conversion. There are a number of standards that either copy or are predecessors of iec 60751. Pot seal or quick connectdisconnect plug and jack or terminal block with ptfe insulated copper conductor flexible tails.
306 733 861 182 756 196 544 1075 1239 542 1129 1323 1303 638 215 1539 1039 246 47 1003 1364 902 875 816 331 1207 1470 685 612 1173 334 1058 906 777 695 1518 844 945 1375 342 655 329 618 859 1209 450 1265 460 1026 1028